molecular devices plate readers. Sale price $18,499. molecular devices plate readers

 
 Sale price $18,499molecular devices plate readers  Recertification service

Our microplate readers and software are the industry’s most cited and have empowered life science researchers to advance protein and cell biology. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers User Guide 0112-0102 Rev. Instrument settings can be saved as a protocol file. W×D×H. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. White plates reflect the light, enabling even low levels of Luminescence to be detected. SpectraMax® 190 Absorbance Plate Reader, Molecular Devices. The VersaMax Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340 nm - 850 nm). The SpectraMax® M2 and M2e Multimode Microplate Readers provide two detection modes in one platform and offer the added functionality of bottom-read fluorescence for cell-based assays. Integrated to. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of. For 40 years, we have partnered with scientists to help them achieve landmark discoveries. SpectraMax iD5 Multi-Mode Microplate Reader, a hybrid monochromator- and filter-based, five-mode plate reader with automatic filter identification and western blot capability. 996 (n = 3) ; for SpectraMax Plus 384 reader, r 2 = 0. SpectraMax M series, Gemini, and SpectraMax iDx readers have xenon flash lamps,. The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Use all black plate. For more sample throughput, both readers can be easily. Cell Cytotoxicity assay procedureMolecular Devices. Increase productivity with patented microplate reader technologies. Every step is optimized for data acquired from a Molecular Devices microplate reader or data imported from. Specifications subject to change without notice. Step 2: Launch SoftMax Pro Software. Tests every subsystem of the reader or . Step 2. Plate stacker and robot integration The Gemini EM Reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. Beyond the hardware, a microplate reader’s software also impacts performance and flexibility. This process should take about 3 - 5 minutes. Molecular Devices' microplate readers. Page 16 FilterMax F3 and FilterMax F5 Multi-Mode Microplate Readers User Guide To exchange an excitation or emission filter in a slide: 1. #SpectraMax L Config) Methods. ensure your reader is thoroughly tested against specifications we consider critical to achieving quality results. Clone Screening. 9. Read one sample or up to 384 in a. SpectraMax Microplate Readers. Eliminate time-dependent substrate addition steps. An IL-22 standard curve was prepared and a sandwich ELISA performed using the MultiWash+ plate washer in strip mode to wash the wells. S. Molecular Devices Software. The plate reader. SoftMax Pro 7. The former have been the traditional domain of plate readers and great strides have been. Our specialized plate readers for absorbance, fluorescence, and luminescence detection provide optimal sensitivity. Turn the reader on and secure the USB cable. Recertification service. The purpose of this procedure is to set instructions in the proper use and handling of the Molecular Devices M5 Plate Reader. Fig 2: Enzymatic response of synthetic compounds. SoftMax Pro GxP Software. Select the Driver tab. Figure 1. The plate reader optics are. Step 4: Incubate at room temperature for 1 hour, protected from light. SoftMax Pro Software is an industry-leading acquisition and analysis software with over 160 ready-to-run protocols, powerful data analysis, and a range of data output options. Get the most out of SoftMax Pro. Learn about the SpectraMax i3x Multi-Mode Plate Reader capabilities and options in this short video. We would like to show you a description here but the site won’t allow us. The plate was then read on Molecular Devices microplate readers with luminescence detection mode (Read A). It also integrates with the. Molecular Devices SpectraMax ® i3x MultiMode Microplate Reader, in combination with luminescent assays for cell viability and cytotoxicity, provides a sensitive and rapid way to measure the number of viable cells in culture and quantify the cytotoxic effects of experimental treatment. They feature options and modules to address your specific research including objectives, filters, imaging modes, and environmental. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. 2. #iD3) Methods. Multimode Microplate Readers. Fluorescence Microplate Reader Comparison Chart. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. 0) at 37 °C, fluorescence intensity was recorded on a Spectramax M5 Multimode plate reader. SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers. Versa. SpectraMax® M5/M5e Multimode Plate Reader, Molecular Devices Supplier: Molecular Devices Description: The SpectraMax® M5 Multi-Mode Microplate Reader delivers. Explore more about the SpectraMax i3x Multi-Mode Plate Reader, a user-upgradeable detection modules allow you to expand the capabilities of your microplate reader when your research requires it. The primary mode is fluorescence. sensitivity or performance. 9. #Flex3) Methods. VMax . Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Read times. Below is the list of Molecular Devices microplate readers and liquid handling instruments that are of out-of-production and are now considered obsolete. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance and can be equipped to read volumes as low as 2uL in one multimode reader package. One plate carrier adapter is provided with the instrument. Molecular Devices announced today the launch of the new SpectraMax ® ABS and ABS Plus Microplate Readers that cover a wide range of absorbance-based applications such as ELISAs, microbial growth, and protein quantitation and can be easily integrated into full robotic systems. Due to their ability to simultaneously measure multiple wells in a single run, fluorescence plate readers are useful for conducting various assays, such as quantitative assays, enzyme assays, and ELISAs. Supersedes 1. S. Because many reagents can be fluorescently labeled, spectrofluorometers are used to detect many biological and chemical processes. 1. Mode Reader with the StakMax Microplate Handling System from Molecular Devices. We would like to show you a description here but the site won’t allow us. Microplates for Molecular Devices Microplate Readers – Photometric Accuracy Fluorescence Intensity Luminescence Intensity (0. StakMax Handling Stacker Base Unit. Our extensive SpectraMax® line of user-friendly microplate readers – the industry’s most cited brand – provide great. Purchase a new SpectraMax Multi-Mode Microplate Reader and. Complete plate reader solution for all your research needs. 2. ©2012 Molecular Devices, LLC | 8/12 | Printed in USA | PN: 0120-1527. PBS was removed, and cell pellets were. Microplate Reader Shelf. Figure 1. Multi-mode Plate Reader. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. #0200-6263) UltraVision™ Plate 384 (Brooks Life Sciences cat. Molecular Devices launches custom organoid line expansion service using unique bioprocess technology for high-throughput applications. Compact designs. #6590-0121) SpectraMax i3x® Multi-Mode Microplate Reader (Molecular Devices cat. The SpectraMax iD5 reader uses the HTRF detection system, which includes an Enhanced TRF Module and filters for excitation and emission. 2, 2022 – Molecular Devices announced today the launch of the ValitaCell IgG titer assay, ValitaTiter, available for global distribution. Page 1 of 8 . Combining multiple microplate technologies and detection modes into a single, more versatile unit may be an ideal choice especially if you have. One plate carrier adapter is provided with the instrument. 0 . For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. The sample is typically placed in a cuvette through which light is sent horizontally. Lab automation for high-throughput plate-based assays. Molecular Devices 推出了FlexStation® 3 多功能读板机系统。FlexStation 3 把 SpectraMax M5e 和 8 道 / 16 道的移液 系统整合在一起成为体积小巧功能强大的 读板机系统。该整合系统不但为用户提供 了多功能检测平台,还增加了液体处理的 通量和提升了检测生化和细胞动. SpectraMax Microplate Readers. Plate layout configuration. • Analyze data in a single plate, across multiple plates, or between different groups. Next generation SpectraMax® absorbance microplate readers. Eight filter options provide simplified assay setup. Microplate Readers. The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. Built-in near-field communication (NFC) reader enables you to pull up your custom protocols and results with a single tap, saving you precious time. Molecular Devices, LLC Optical System: Inquire; Measuring Time: White light - 96-well/ 384 well microplate: <2 min Fluorescence - 96-well/ 384 well microplate: <8 min. Preventive Maintenance (PM) Each plate reader or washer is calibrated, inspected, and lubricated— any potential issues are. FlexStation™ II Systems provide integrated fluid transfer capability from a source platePlate Reader SpectraMax iD5 multi-mode system Plate Washer AquaMax 4000 Microplate Washer Robot PreciseFlex 400 Sample Handler Plate Storage Plate Hotels – 40 microtiter plates Controlling Software Genera Control Software Incubation LiCONiC STX44 Automated CO 2 Incubator Liquid Handler Microlab STAR Automated Liquid Handling The. 40266 Email: drugdiscoverytech@lifetech. To update the driver. The Bauer Core Facility at Harvard University offers of variety of plate-reader choices to its users (mostly from Molecular Devices), and the SpectraMax® L is. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. They provide absorbance, fluorescence, glow luminescence, and other read modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements. These robust readers have been placed in labs from. 9. The user must ensure that the meniscus is comfortably above the light beam in standard cuvettes and that the sample chamber in a microcuvette is aligned properly with the beam. Table 1: FLIPR hardware settings for a cell plate basal fluorescence signal test. Search. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers Molecular Devices LLC Applications: Absorbance, Cell Health, Cell Viability, Cellular. SpectraMax® Microplate Readers and SoftMax® Pro Software. GxP. . After centrifugation, the plate was immediately read on the M5e and i3x readers using the instrument settings listed in Table 1. Flexibility to read a variety of plate formats - SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. Details. To maintain confidence in the standards, Molecular Devices recommends having validation plates recertified at one-to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, and Luminescence is the emission of light by a substance as a result of a chemical reaction called chemiluminescence or an enzymatic reaction called bioluminescence. A plate reader’s software may offer automated analysis using protocols configured for a particular assay. Ensure data accuracy of your reader. 1 sec. The SpectraMax® Paradigm® Multi-Mode Microplate Reader measures absorbance, fluorescence, time-resolved fluorescence (including HTRF), fluorescence polarization, AlphaScreen®, AlphaLISA®, and luminescence assays for up to 1536-well plates. , attenuation mode = out. 2. With SpectraMax Mini Reader Plug-In Download Page (required for SoftMax Pro 7. 304 signal level saturation. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices. . 635. 과 같은 Parameter를 검사하여 평가할 수 있습니다. Molecular Devices' microplate readers. Flip open the carriage door and using a flash light to check where the plate is stuck and whether it has been damaged. NORTH AMERICA. 0200-6262. For researchers working in GLP or GMP laboratories, achieve full GxP compliance with our turnkey solution:. The 1/absorptivity value for double stranded DNA at 260 nm is commonly assumed to be \~50 µg/mL for a 1-cm pathlength3,4. That’s why Molecular Devices offers the following services: Installation qualification (IQ), operational qualification (OQ), preventive maintenance (PM), and repair coverage. Molecular Devices' microplate readers. SoftMax Pro’s 21 curve fit options, including 4-parameter logistic and 5-parameter logistic models, and the ability to assign multiple standard curves within the same plate make it easy to interpolate unknown samples or perform parallel line analysis (PLA) to determine relative potency. , target CV per well = 1. We would like to show you a description here but the site won’t allow us. Absorbance was read at 590 nm on the SpectraMax ABS Plus Microplate Reader. Click on each for more information. Step 3: Wash microplate – Unbound material is washed away, leaving only the antigen of interest. Multi-mode Microplate Readers. Microplate Readers. Gemini XPS & EM readers measure fluorescence on a variety of sample formats from 6- to 384-well. Urban myths of microplate readers. Page 1 ™ VERSAmax Tunable Microplate Reader Operator’s Manual for Instruments with Serial Numbers Beginning with BN Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0084 Rev. 2. By using PathCheck, SpectraMax readers can automatically normalize sample absorbance values to a 1-cm pathlength and calculate the concentrations. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers. 997 (n = 3). 0112-0115J 9 Chapter1:Introduction TheSpectraMax®M3Multi-ModeMicroplateReader,SpectraMax®M4Multi-ModeMicroplate Reader,SpectraMax®M5Multi-ModeMicroplateReader,andSpectraMax®M5eMulti-Mode The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. Complete plate reader solution for all your research needs For over 40 years, we have partnered with scientists to expand the boundaries of their research. The ScanLater Western Blot Detection Cartridge is a user-installable option for the SpectraMax i3, i3x and Paradigm Multi-Mode Readers. The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm) with 4 filter choices included at time of purchase. 384 deep well plate: packed in sleeves of 6 , 24 per case. Validating the absorbance optical performance of your microplate reader is as simple as reading a plate. 340 PC384. 2 GxP Software is our most secure software to help you achieve full FDA 21 CFR Part 11 compliance with streamlined workflows to ensure data integrity. With optimized reagents and the industry-leading data acquisition and analysis tool, SoftMax Pro® 7 Software, the SpectraMax® iD3. This technical note demonstrates validation of the SpectraMax® i3x Multi-Mode Microplate Reader for NanoBRET™ assays. SpectraMax ABS Plus Microplate Reader (Molecular Devices cat. SOP Title: Use and Maintenance of a Molecular Devices M5 Plate Reader Document ID: HSL_EQ_005 Version 2. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance in one multimode reader package. View SoftMax Pro GxP. Devices PathCheck® Sensor—the only patented technology available that measures the depth (optical pathlength) ofWe would like to show you a description here but the site won’t allow us. Only SoftMax Pro 5 or older versions. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. , Nov. 96-deep-round-well-plate, 384-deep-square-well-plate, 24-deep-well-plates. FlexStation 3 Multimode Microplate Reader (Molecular Devices Cat. Instrument settings can be saved as a protocol file. Read the plate on the SpectraMax M5, M5e, or FlexStation 3 reader using the optimized settings shown above. This five-mode microplate reader with automatic filter identification and western blot capability is the complete. We would like to show you a description here but the site won’t allow us. 305 reference level saturation. Step 3: Click “Settings” and a screen will appear (Figure 1). Turn on Plate Reader and wait for it to complete its start-up routine. Molecular Devices SoftMax ® Pro software was used to analyze and present the data. ELISA Workflow Using the EMax plus Microplate Reader and MultiWash+ Microplate Washer. Luminescence detection typically offers greater sensitivity than absorbance or fluorescence detection. To maximize sensitivity of the assay, it is necessary to use optimal excitation and emission wavelengths. Absorbance microplate readers from Molecular Devices are used to detect the absorbance in the melamine assay. In an analogous manner, the same sample names were assigned to a CuvetteSet section. This can increase throughput and efficiency, thus saving time and space in the lab. , Sunnyvale, CA 94089, USA, Jin_Liao@moldev. Wide photometric range Temperature-regulated Thermal control and vertical shake Microsoft Windows-based software Automatic mixing Five-second read per plate Photometric and kinetic analysis mode The Molecular Devices ThermoMax is an efficient, temperature-regulated, 96 well microplate reader. Unplug the power cable from the back of the instrument. coli stock with an OD 600 value of 0. 18 kg. SpectraMax Microplate Reader - Choose from our extensive SpectraMax® line of user-friendly microplate readers. Fig 2: Enzymatic response of synthetic compounds. Select Update Driver. 0 . The Analyst®, FlexStation® and SpectraMax® M5/M5 e from Molecular Devices have received the LanthaScreen® Certified designation from Life Technologies which ensures that these readers are validated to strict standards in instrument setup and assay performance. If flexibility becomes important in a growing lab supporting a variety of projects, the decision might come down to whether. The AquaMax® Microplate Washer is a fully self-contained system, configurable for both 96- and 384-well microplates. 0) OD (500 to 1100) RFU (5. The SpectraMax ABS. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers User Guide 0112-0102 Rev. Recombinant protein expression Nucleocapsid. PURPOSE. 9. 0200-6263. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. The purpose of this procedure is to set instructions in the proper use and handling of the Molecular Devices M5 Plate Reader. Built-in Help function answers your most frequently asked questions. #6590-0108) Fluorescence detection using the SpectraMax iD5 reader’s monochromators for wavelength selection was compared to that using a filter pair specific for the Alexa594 tracer. Unlike filter-based plate readers, the dual monochromators in the SpectraMax iD5 Multi-Mode Microplate Reader and other SpectraMax readers allow the selection of any wavelength within the reader’s stated range. Endpoint, kinetic, spectrum. the standard plate reader applications, protecting your initial investment. The BCA assay plate was read at 562 nm, the original wavelength setting in the protocol, while for the BCA Rapid. The procedures for these tests are outlined in the instrument user manual. These tools can be used in conjunction with SoftMax® Pro Software validation package and IQ/OQ/PQ validation protocols for FDA 21 CFR Part 11 compliance. The FilterMax™ F3 and F5 Multi-Mode Microplate Readers offer a wide set of features at an affordable price-to-performance ratio. Select Start>Control panel>Device Manager. Products : General, FilterMax F5 reader. #0200-7009) Optimal instrument settings for ValitaTiter (P/N VAL003 or VAL013, left table) and ValitaTiter Plus (P/N VAL004 or VAL014, right table) assays on the SpectraMax i3x reader are shown below. Part Number Description 1-2100-0548 USB computer connection cable, 3 meter (9. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. We therefore gathered salient. 0 OD for our latest microplate readers, SpectraMax® iD3, iD5, ABS, and ABS Plus readers, and up to 2. With the novel filter system, assays such as hydrogen peroxide detection assays and IRantibody-binding assays can be run confidently with Molecular Devices. 211, and 820 and EudraLex Volume 4 and Annex 11 and 15, and how they apply to the implementation of Molecular Devices microplate readers and SoftMax Pro. Monthly Plate Verification Check (Absorbance Validation Plate) Note: Monthly Plate Verification Check is maintained by Quality Control. Fluorescence Filter with holder 565nm BW 30nm (Molecular Devices cat. Create custom fluorescence assays without having to purchase expensive filter sets. 020 OD 2. In this unique new five-part weekly webinar series, running every Thursday throughout October 2020, we’ll introduce you to various aspects of microplate reader technology in an educational and entertaining way! Starting with some basic concepts,. The optical system of the SpectraMax 190 Microplate Reader is built around a monochromator, which allows for selection of up to six wavelengths at a time for absorbance detection in the UV-visible wavelength range (190 nm - 850 nm). Molecular Devices training courses and tutorials. SpectraMax® Microplate Readers and SoftMax® Pro Software. Published Dec 16, 2020 | Updated Dec 16, 2020. The temperature in the plate chamber is ambient and isothermal. Introduction. The user guide also covers the software features, the maintenance procedures, and the technical specifications of the readers. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. Plate reader settings used for data acquisition of bacterial growth curve. Figure 2. , prior to compound addition) from the cells. M2. LMax and LMax II plate readers use photon counting mode similar to the SpectraMax L reader. The calculated LOQ values were 0. Your applications, your modes, your choice. Made from polypropylene with conical well profiles to maximize recovery and allow working with sample volumes as low as 5 µl. The Back Panel Figure 1. Or, with the reader specifications noted from the Instrument. The opaque walls prevent stray light from being detected from neighbouring wells for best accuracy. Step 4: Add detection antibody – Enzyme-conjugated detection antibody binds to a second site on the. Use form “26003-02: Molecular Devices Plate Reader Plate Calibration Form” to record material and equipment information. One plate carrier adapter is provided with the instrument. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Our SpectraMax microplate readers and SoftMax Pro software are the industry's most cited and have empowered life science researchers to advance protein and cell biology―breaking the. 0%, raw data units = counts/sec. Our 15 years of experience means we understand these instruments as well as the manufacturer, and it allows us to provide top-quality service. you might consider 300 W (at 120 Volts) per Spectramax reader, plus another 300 W for the Computer. The touchscreen interface provides integrated instrument control, data display, and the ability to export results over your network for statistical data analysis. Microplate Reader, Multimode Molecular Devices SpectraMax M2e Multi-Mode Microplate Reader w/ SoftMax Pro. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader s with all This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. 944. Get any of the iD series microplate readers with up to 25% discount off the current list price in their basic configuration and receive a two-year warranty for commercial or a three-year warranty for Academic customers. Tests every subsystem of the reader . SoftMax® Pro 7. For biochemical assays, the washer removes unbound material and unreacted reagents. 더 많은. absorbance plate readers. These models can no longer be repaired. . Details. 0 software Download page. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. The ability to accurately quantitate cell number in multi-well microplates enables a multitude of biological applications that study cell health or proliferation. Here, the CVs for each plate were less than 3, and the difference between mean onset time for the plates run on the two readers was only 7%. Successful targets include calcium channels, chemokine receptors, and transiently transfected receptors. 96 deep well plate: packed in sleeves of 6 , 24 per case. These systems are hybrids that allow you to choose between. Detection modalities include absorbance (UV-Vis Abs), fluorescence intensity (FI), luminescence (Lumi), and all have. July 17, 2023. 425 or. With three modes of detection for UV/Vis absorbance, fluorescence and luminescence, the SpectraMax®. Instrument settings can be saved as a protocol file. Small but mighty absorbance plate reader •ffordable monochromator-based plate reader with linearity A of up to 3 OD • orks with 96- and 384-well plates as well as cuvettes W. M2. 5 hours. ] Example of document to evaluate if the reader . On LabX buyers can find a variety of SpectraMAX models for sale: 190, 384, 340 and the SpectraMAX M series. degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. begin reading microplates with seven mouse clicks. SoftMax Pro GxP, together with a Molecular Devices plate reader and Molecular Devices GxP Admin software, provides a fully integrated hardware and software solution for . The SpectraMax iD5 reader uses the HTRF detection system, which includes an Enhanced TRF Module and filters for excitation and emission. Five-mode microplate reader with automatic filter identification and western blot capability The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance, fluorescence, luminescence, time-resolved fluorescence (TRF), and tunable fluorescence. Flexibility to read a variety of plate formats. SOP Title: Use and Maintenance of a Molecular Devices M5 Plate Reader Document ID: HSL_EQ_005 Version 2. The SpectraMax M2/M2e User Guide is a comprehensive manual that provides detailed instructions on how to operate, maintain, and troubleshoot the SpectraMax M2 and M2e microplate readers. (b) Fluorescence responses of probe HADP and control compounds 2–4 (each 5 µM) towards human heparanase (HPA) (1 µg) in 40 mM NaOAc buffer (pH 5. SOP Title: Use and Maintenance of a Molecular Devices M5 Plate Reader Document ID: HSL_EQ_005 Version 2. A plate containing two columns each of 75 µL, 100 µL, 150 µL, 200 µL, 250 µL, or 300 µL of yellow buffer solution was read at 426 nm on a SpectraMax microplate reader. . The ultimate guide to microplate readers is an eBook that tells you everything you need to know about plate reader solutions from what a microplate reader is, to popular applications and technology, to GxP compliance and special tips and tricks to help maximize your. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Wide photometric range Temperature-regulated Thermal control and vertical shake Microsoft Windows-based software Automatic mixing Five-second read per plate Photometric and kinetic analysis mode The Molecular Devices ThermoMax is an efficient, temperature-regulated, 96 well microplate reader. Other features and benefits include: Eliminate changing out filters. SpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. Select Update Driver. Cell line development teams will realize savings on time and resources,SpectraMax i3x. Microscopes and Microplate Instrumentation. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Molecular Devices provides the complete solution covering the instrument and software: • SpectraTest® ABS1, FL1, and LM1 Validation Plates for hardware validation of absorbance, fluorescence, and luminescence modes • IQ/OQ for all microplate readersSpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The SpectraMax ABS Plus reader utilizes Molecular . Fig 2: Enzymatic response of synthetic compounds. This reader utilizes Molecular Devices' patented PathCheck® Sensor to measure the depth (optical pathlength) of samples in a microplate. 5577 UK +44. Read height should be optimized forIMAP phosphodiesterase assays on SpectraMax Multi-Mode Microplate Readers. For a higher . 2. The ultimate guide to microplate readers is an eBook that tells you everything you need to know about plate reader solutions from what a microplate reader is, to popular. 3. Molecular Devices i3x. It then uses the pre-defined settings for the specified instrument to build a protocol. 9000-0756. to that of dedicated single-mode readers. UV/Vis spectrophotometer & microplate reader with built-in cuvette port. The SpectraMax M2 and M2e are versatile and reliable instruments that can perform a range of applications in. Important things to consider when purchasing a multimode microplate reader. The reader measures both flat and round 96-well microplates and.